ONLINE HELP
 WINDEVWEBDEV AND WINDEV MOBILE

This content has been translated automatically.  Click here  to view the French version.
Help / Tools / Monitoring robot / Robot
  • Overview
  • Wizard for installing the monitoring robot
  • Installing the robot
  • Configuring the monitoring robot
WINDEV
WindowsLinuxJavaReports and QueriesUser code (UMC)
WEBDEV
WindowsLinuxPHPWEBDEV - Browser code
WINDEV Mobile
AndroidAndroid Widget iPhone/iPadIOS WidgetApple WatchMac Catalyst
Others
Stored procedures
Installing the monitoring robot
Overview
The monitoring robot includes three executables.
The first executable to install is the executable corresponding to the robot. The monitoring robot is always started on a computer and it runs all the requested tests. It must be installed on a computer that is never turned off.
The second executable is the robot controller (or Robot controller). Its setup is optional. The Robot controller is an additional security tool. It is used to check whether the monitoring robot operates properly. If it is installed, the Robot controller must be installed on a computer that will never be switched off, different from the setup computer of the monitoring robot.
The third executable is the robot monitor. The monitor can be installed on any computer. It is used to edit the tests and the different parameters of the robot.
Wizard for installing the monitoring robot

Installing the robot

To install the monitoring robot:
  1. Run the installation package (WX2025PACKROBOT.EXE) on the computer where the monitoring robot is to be installed. Reminder: The installation package (WX2025PACKROBOT.EXE) is available in the "Install\Robot" subdirectory of the product used.
  2. In the setup wizard, accept the terms of license agreement and go to the next step.
  3. Select "Install the monitoring robot" and go to the next step.
  4. Select the installation directory of the monitoring robot. Go to the next step.
  5. The setup is completed. Validate. The monitoring robot is installed. All you have to do now is configure the monitoring robot.

Configuring the monitoring robot

Once the monitoring robot is installed, a wizard is automatically displayed to configure the monitoring robot.
  1. Specify the robot name. This name will be used in the different status reports and messages sent. We advise you to use a name that can be easily identified. Go to the next step.
  2. Specify whether a Robot controller will be deployed. The Robot controller is used to regularly check the activity of the monitoring robot. The setup of a Robot controller is not mandatory but it is an additional security.
    If a Robot controller must be installed, specify the name of the computer where the Robot controller will be installed.
    Go to the next plane.
  3. Select the alert options of the monitoring robot. These options will be used by default for all the tests run by the monitoring robot. You can:
    • use WINDEV, WEBDEV and WINDEV Mobile's internal messaging system: WDBal. This option assumes that the database of the Control Centers is accessible from the computer of the monitoring robot.
    • send the messages by email. This option assumes that the computer of the monitoring robot can access an email server.
    • use another program, that will perform a specific process of the messages. This other program must be accessible from the computer of the monitoring robot.
      If none of these options was selected, the only alert will be a sound and visual alert on the monitor.
      These options can be modified at any time from the monitor.
  4. Go to the next plane. This plane depends on the options that were previously checked.
    • If the WDBal messaging must be used, specify:
      • the name of message sender (and the associated password if necessary). This name must correspond to the name of a contributor found in the database of Control Centers.
      • the default recipients. The name specified in the table must correspond to the name of a contributor found in the database of Control Centers.
        Note: For each test, new recipients can be added.
      • the parameters for accessing the database of Control Centers:
        • directory of the database if the files use a network share.
        • characteristics of the HFSQL Client/Server database (server, port, database).
    • If an email must be sent, specify:
      • the sender email address. This address is the one displayed in the email.
      • the characteristics of the SMTP server to be used to send messages: server, port, user and associated password (these characteristics are supplied by the ISP).
      • the email addresses of default recipients.
        Note: For each test, new recipients can be added.
    • If another program must be used, specify the path of the executable to run.
  5. Specify the Windows account (and the associated password) used to create the scheduled task that will start the monitoring robot. Please note: this account must have administrative rights to perform this operation..
    If a domain is used, specify the domain name.
    Remark: If domain names are used, all three programs (robot, counter-robot and monitor) must be installed on the same domain..
    Go to the next plane.
  6. Specify the name of the shared directory ("MyRobot" for example) that will allow the monitors (installed on other computers) and/or the Robot controller to access the test data. This directory will be created on the current computer and automatically shared.
  7. The setup is completed. Validate. The setting of the monitoring robot is performed.