Writes one or more single-precision floats to a Modbus slave, starting at a specific address.
Remarks:
  • This function is used to write one or more single-precision floats in contiguous registers in the slave.
  • This function blocks the application until the slave acknowledges the message or until the session timeout is exceeded.
  • The writing of one or more floats corresponds to Modbus function code 16 (Write Multiple Holding Registers)..
Example
// Create a session and connect to a Modbus server
Session is modbusSession
Session = ModbusConnectTCP("192.168.1.7")

// If the connection fails, display the error
IF ErrorOccurred = True THEN
Trace(ErrorInfo())
ELSE
// Write a sequence of 5 floats starting at address 0x42
IF NOT ModbusWriteFloat(Session, 0x42, [1.5, 3.1415, 2.718, -15, 0.0], modbusABCD) THEN
Trace(ErrorInfo())
END
END

// Disconnection
ModbusDisconnect(Session)
Syntax

Writing 1 single-precision float to a Modbus slave Hide the details

<Result> = ModbusWriteFloat(<Session> , <Address> , <Floating> , <Endianness>)
<Result>: Boolean
  • True if written successfully,
  • False otherwise. To get more details on the error, use ErrorInfo with the errMessage constant.
<Session>: modbusSession variable
Name of the modbusSession variable that corresponds to the communication session with the Modbus slave.
<Address>: Integer
Value between 0 and 65,535 that corresponds to the address (slave) to which the single-precision float must be written.
<Floating>: Real
Value of the single-precision float to be written to the register.
<Endianness>: Integer constant
Mode for storing float values on the slave device. Bytes are identified from A to D. A is the most significant byte and D is the least significant byte (IEEE-754 standard).
modbusABCDThe sent bytes are stored the same order on the slave device.
modbusBADCThe sent bytes are swapped 2 by 2 on the slave device.
modbusCDABThe sent bytes are swapped 2 by 2 on the slave device.
modbusDCBAThe sent bytes are swapped on the slave device.

Writing multiple single-precision floats to a Modbus slave Hide the details

<Result> = ModbusWriteFloat(<Session> , <Address> , <Floats to be sent> , <Endianness>)
<Result>: Boolean
  • True if written successfully,
  • False otherwise. To get more details on the error, use ErrorInfo with the errMessage constant.
<Session>: modbusSession variable
Name of the modbusSession variable that corresponds to the communication session with the Modbus slave.
<Address>: Integer
Value between 0 and 65,535 that corresponds to the address (slave) to which the single-precision floats must be written.
<Floats to be sent>: Array
Name of the array of single-precision reals to be sent.
<Endianness>: Integer constant
Mode for storing float values on the slave device. Bytes are identified from A to D. A is the most significant byte and D is the least significant byte (IEEE-754 standard).
modbusABCDThe sent bytes are stored the same order on the slave device.
modbusBADCThe sent bytes are swapped 2 by 2 on the slave device.
modbusCDABThe sent bytes are swapped 2 by 2 on the slave device.
modbusDCBAThe sent bytes are swapped on the slave device.
Remarks
CAUTION: As writing operations involve the manipulation of automation devices, it is advisable to test the various commands before putting them into production, to ensure that the devices perform the required operations.