Sends a command to one or more electrical devices compatible with the X10 protocol.
Note: In order for the X10 protocol to operate properly through power-line carrier, continuous power is required between the devices. For example, the transmission cannot pass through an insulation transformer.
Example
// Open the X10 connection
ConnectionID is int
ConnectionID = DomoOpen("COM4", "A")  
// Switch on the lamps connected to the A3 and A4 modules
DomoSend(ConnectionID, "A3 A4", domoOn)
// Equivalent to: DomoSwitchOn(ConnectionID, "A3 A4")
// Modify the intensity of these lamps
DomoSend(ConnectionID, "A3 A4", domoDim, -60)
// Equivalent to: DomoSend(ConnectionID, "A3 A4", domoModify, -60)
...
// Switch off the lamps
DomoSend(ConnectionID, "A3 A4", domoOff)
// Equivalent to: DomoSwitchOff(ConnectionID, "A3 A4")
// Switch off all the devices on A
DomoSend(ConnectionID, "A", domoAllOff)
Syntax
<Result> = DomoSend(<Connection Identifier> , <Address> , <Command to Send> [, <Command Value>])
<Result>: Boolean
  • True if the command was successfully sent,
  • False otherwise (transmission error, device did not respond, ...). To find out the error details, use ErrorInfo associated with the errMessage constant.
<Connection Identifier>: Integer
Identifier of the connection to use. This identifier is defined by DomoOpen.
<Address>: Character string (with quotes)
Address of the electrical devices compatible with the relevant X10 protocol.
The format of an address is as follows: <House code><Module code>
Where:
<House code> corresponds to a letter found between A and P.
<Module code> corresponds to a number found between 1 and 16.
For example: "A1", "B14".
To specify several addresses, the addresses must be separated by a space character. For example: "A1 A3 B15".
<Command to Send>: Integer constant
Command that must be sent to the specified electrical devices:
domoAllOffSwitches all the specified electrical appliances off. In this case, <Address> must only contain one or more house codes.
domoOffSwitches the specified electrical appliances off.
domoBrightIncreases the intensity of the specified electrical devices by <Command Value> percent (brightness of the lamps in most cases).
domoDimReduces the intensity of the specified electrical devices by <Command Value> percent (brightness of the lamps in most cases).
domoOnSwitches the specified electrical appliances on.
domoModifyModifies the current status of the specified electrical appliances. In this case, <Command Value> corresponds to:
  • True: Switches the specified electrical appliances on.
  • False: Switches the specified electrical appliances off.
  • <Positive Value>: Increases the intensity of the specified electrical devices by <Positive Value> percent
  • <Negative Value>: Reduces the intensity of the specified electrical devices by <Negative Value> percent
<Command Value>: Optional boolean or integer
Value of the command sent:
TrueSwitches the specified electrical appliances on.
FalseSwitches the specified electrical appliances off.
<Positive Value>Increases the intensity of the specified electrical devices by <Positive Value> percent.
<Negative Value>Reduces the intensity of the specified electrical devices by <Negative Value> percent.